A list of standards maintained by the PSRC. Click on column headers to sort the table.
Standard Number | Subcommittee | Title |
---|---|---|
1613 | I | Standard Environmental and Testing Requirements for Communications Networking Devices Installed in Electric Power Substations |
P1613 | I | Standard for Environmental and Testing Requirements for Intelligent Electronic Devices (IEDs) Installed in Transmission and Distribution Facilities |
1613.1 | I | Standard Environmental and Testing Requirements for Communications Networking Devices Installed in Transmission and Distribution Facilities |
1613a | I | IEEE Standard Environmental and Testing Requirements for Communications Networking Devices Installed in Electric Power Substations Amendment: Adding of one definition, DC power supply requirements (5.1), and Annex E- History |
1646 | H | Standard Communication Delivery Time Performance Requirements for Electric Power Substation Automation |
P1646 | H | Standard Communication Delivery Time Performance Requirements for Electric Power Substation Automation |
P2030.12 | H | Guide for the Design of Microgrid Protection Systems |
2030.1 | H | Recommended Practice for Implementing an IEC 61850 Based Substation Communications, Protection, Monitoring and Control System |
P2030.100.1 | H | Monitoring and Diagnostics of IEC 61850 Generic Object Oriented Status Event (GOOSE) and Sampled Values Based Systems |
2030.101 | H | Guide for Designing a Time Synchronization System for Power Substations |
60255-118-1 | H | Measuring Relays and Protection Equipment - Part 118-1: Synchrophasor for Power System - Measurements |
C37.1 | H | Standard for SCADA and Automation Systems |
PC37.1.2 | H | Recommended Practice for Databases Used in Utility Automation Systems |
PC37.1.3 | H | Recommended Practice for Human Machine Interfaces (HMIs) used with Electric Utility Automation Systems |
C37.2 | I | Standard Electrical Power System Device Function Numbers, Acronyms and Contact Designations |
PC37.2 | I | Standard Electrical Power System Device Function Numbers, Acronyms, and Contact Designations |
C37.90 | I | Standard for Relays and Relay Systems Associated with Electric Power Apparatus |
PC37.90 | I | Standard for Relays and Relay Systems Associated with Electric Power Apparatus |
C37.90.1 | I | Standard Surge Withstand Capability (SWC) Tests for Relays and Relay Systems Associated with Electric Power Apparatus |
C37.90.2 | I | Standard for Withstand Capability of Relay Systems to Radiated Electromagnetic Interference from Transceivers |
PC37.90.2 | I | Standard for Withstand Capability of Relay Systems to Radiated Electromagnetic Interference from Transceivers |
C37.90.3 | I | Standard for Electrostatic Discharge Tests for Protective Relays |
C37.91 | K | Guide for Protecting Power Transformers |
PC37.91 | K | Guide for Protecting Power Transformers |
C37.92 | I | Standard for Analog Inputs to Protective Relays From Electronic Voltage and Current Transducers |
PC37.92 | I | Standard for Analog Inputs to Protective Relays From Electronic Voltage and Current Transducers |
C37.95 | K | Guide for Protective Relaying of Utility-Consumer Interconnections |
C37.96 | J | Guide for AC Motor Protection |
C37.98 | I | Standard for Seismic Qualification Testing of Protective Relays and Auxiliaries for Nuclear Facilities |
C37.99 | K | Guide for the Protection of Shunt Capacitor Banks |
PC37.99 | K | Guide for the Protection of Shunt Capacitor Banks |
C37.101 | J | Guide for Generator Ground Protection |
PC37.101 | J | Guide for Generator Ground Protection |
C37.101-2006/Cor 1 | J | Guide for Generator Ground Protection - Corrigendum 1: Annex A.2 Phasor Analysis (Informative) |
C37.102 | J | Guide for AC Generator Protection |
PC37.102 | J | Guide for AC Generator Protection |
C37.103 | I | Guide for Differential and Polarizing Relay Circuit Testing |
C37.104 | D | Guide for Automatic Reclosing of Circuit Breakers for AC Distribution and Transmission Lines |
PC37.104 | D | Guide for Automatic Reclosing on AC Distribution and Transmission Lines |
C37.105 | I | Standard for Qualifying Class 1E Protective Relays and Auxiliaries for Nuclear Power Generating Stations |
C37.106 | J | Guide for Abnormal Frequency Protection for Power Generating Plants |
PC37.106 | J | Guide for Abnormal Frequency Protection for Power Generating Plants |
C37.108 | K | Guide for the Protection of Network Transformers |
PC37.108 | K | Guide for the Protection of Secondary Network Systems |
C37.109 | K | Guide for the Protection of Shunt Reactors |
PC37.109 | K | Guide for the Protection of Shunt Reactors |
C37.110 | I | Guide for the Application of Current Transformers used for Protective Relaying Purpose |
PC37.110 | I | Guide for the Application of Current Transformers Used for Protective Relaying Purposes |
C37.110-2007/Cor 1 | I | IEEE Guide for the Application of Current Transformers Used for Protective Relaying Purposes - Corrigendum 1: Corrections to Equation 18 and Equation 19 |
C37.111 | H | Standard for Common Format for Transient Data Exchange (COMTRADE) for Power Systems |
C37.112 | K | Standard Inverse-Time Characteristic Equations for Overcurrent Relays |
C37.113 | D | Guide for Protective Relay Applications to Transmission Lines |
C37.114 | D | Guide for Determining Fault Location on AC Transmission and Distribution Lines |
C37.116 | K | Guide for Protective Relay Application to Transmission-Line Series Capacitor Banks |
C37.117 | C | Guide for the Application of Protective Relays Used for Abnormal Frequency Load Shedding and Restoration |
C37.119 | K | Guide for Breaker Failure Protection of Power Circuit Breakers |
PC37.120 | C | Protection System Redundancy for Power System Reliability |
C37.230 | D | Guide for Protective Relay Applications to Distribution Lines |
PC37.230 | D | Guide for Protective Relay Applications to Distribution Lines |
C37.231 | I | Recommended Practice for Microprocessor-based Protection Equipment Firmware Control |
C37.232 | H | Standard for Common Format for Naming Time Sequence Data Files (COMNAME) |
C37.233 | C | Guide For Power System Protection Testing |
PC37.233 | C | Guide for Power System Protection Testing |
C37.234 | K | Guide for Protective Relay Applications to Power System Buses |
PC37.234 | K | Guide for Protective Relay Applications to Power System Buses |
C37.235 | I | Guide for the Application of Rogowski Coils used for Protective Relaying Purposes |
PC37.235 | I | Guide for the Application of Rogowski Coils Used for Protective Relaying Purposes |
C37.237 | H | Standard Requirements for Time Tags Created by Intelligent Electronic Devices - COMTAG(TM) |
C37.239 | H | Standard for Common Format for Event Data Exchange (COMFEDE) for Power Systems |
C37.241 | I | Guide for Application of Optical Instrument Transformers for Protective Relaying |
C37.242 | C | Guide for Synchronization, Calibration, Testing, and Installation of Phasor Measurement Units (PMU) for Power System Protection and Control |
PC37.242 | C | Guide for Synchronization, Calibration, Testing, and Installation of Phasor Measurement Units (PMUs) for Power System Protection and Control |
C37.243 | D | Guide for Application of Digital Line Current Differential Relays Using Digital Communication |
C37.245 | K | Guide for the Application of Protective Relaying for Phase Shifting Transformers |
C37.246 | C | Guide for Protection Systems of Transmission to Generation Interconnections |
C37.247 | C | Standard for Phasor Data Concentrators for Power Systems |
C37.248 | H | Guide for Common Format for Naming Intelligent Electronic Devices (COMDEV) |
PC37.249 | H | Guide for Categorizing Security Needs for Protection and Automation Related Data Files |
PC37.250 | C | Guide for Engineering, Implementation, and Management of System Integrity Protection Schemes |
PC37.251 | H | Standard for Common Protection and Control Settings or Configuration Data Format (COMSET) |
PC37.252 | C | Guide for Testing Automatic Voltage Control Systems in Regional Power Grids |
PC37.300 | H | Guide for Centralized Protection and Control (CPC) Systems within a Substation |
C57.13.1 | I | Guide for Field Testing of Relaying Current Transformers |
C57.13.3 | I | Guide for Grounding of Instrument Transformer Secondary Circuits and Cases |